At the end of the selection, began to install the LED tube light, there may be a series of construction problems. The offer for these led downlights installation problem solution, let's look at the correct canister light installation method. Canister light installation method 1, according to the size of hole open circular lamp hole in the ceiling; 2, pull out the power supply cord, the power cord adaptor with lamps and lanterns, pay attention to the connection must be strong, and not easy to loose; 3, hand hold the lamps and lanterns is installed on both sides of shrapnel, and pressure in the middle of the mounting holes, into the ceiling; 4, depending on the installation of shrapnel stretch of lamps and lanterns, locating on the smallpox, trial turning surface cover, feel its strength and tightness; 5, tear open the light, please turn off the power supply, with holding the lamps and lanterns lamp mouth, hold down the cover, push the drop-down. Tube lamp installation note 1, open the barrel lamp after packaging need to pay attention to check whether the product is in good condition, including installation card buckle etc. 2, must cut off the power before installation, make sure the switch in the closed state, to prevent electric shock. After open the switch, do not touch the surface of lamp. Canister light installation should be avoided in the heat source and thermal steam, corrosive gas, so as not to affect the actual service life. 3, before use please confirm good applicable according to the number of power supply. 4, canister light usually use the high pressure ( 110V/220V) Power lamp cup, unfavorable work under frequent power tong, it will affect their life. 5, to the installation environment has exquisite: common tube light should be installed on no vibration, no, no fire hazard level ground, avoid high drop, hard object collisions, rap. When some special place to install the tube light, Such as resonance coefficient larger high-speed) , must choose to have highly shockproof device LED tube light. 6, such as long-term outage, canister light should be stored in a cool, dry, clean environment, banned in damp, high temperature or storage and use of flammable and explosive place. In this look at several special cases, and the corresponding solutions. Problem a: lamp, open hole is not in conformity with the requirements 1, ( l) Lamp installation deviation, not on the center point. ( 2) The levelness of the rows of lamps and lanterns, the straightness deviation is bigger. ( 3) Jane lamp hole greatly smallpox condole top, not neat. 2, root cause analysis ( l) led downlights was not set well hole size, hole, round hole diameter is not unified, etc. ( 2) Construction personnel is not strong sense of responsibility, construction and acceptance of the existing norms, quality inspection evaluation standard are not familiar with. ( 3) Embedded lamp box when the position is wrong, there is deviation, install lamps and lanterns without to take remedial measures. 3, improvement measures, l) Before install lamps and lanterns, should seriously find center, rectify the deviation. ( 2) Strictly regulate lamp hole position deviation degree, the rows of lamps and lanterns installation deviation should not be greater than 5 mm, therefore, need to stay in the construction of localization, the lamps and lanterns in vertical, horizontal, oblique and Lord with low levels are in a straight line. ( 3) Smallpox condole top LED downlight opening to set coordinates, in addition to the required straight, neat and equally, the size of the hole should conform to the specifications of the canister light, not too big, to ensure that the outer ring when the tube lamp installed firmly against condole top, not crack. Problem two: the installation of embedded parts, lamps and lanterns is fixed do not conform to the requirements of 1, ( 1) LED tube light, embedded parts in too deep, different level; Mask there is crack between the wall and the calibre of the lamps and lanterns, lac pollution, not flat. ( 2) Between the lamp body and the ceiling with mortar, not clean up debris. ( 3) LED spotlights, fixed bolt is loose. 2, root cause analysis ( 1) Embedded box without reliable fixation, template expansion mode, installation time coordinates are not accurate. ( 2) Construction personnel is not strong sense of responsibility, the use of electrical safety importance understanding insufficiency, convenience, and there is no clear mortar sundry. ( 3) The unreasonable lamp technology, no accurate reliable fixed box. 3, improvement measures when embedded box is deep, should be equipped with a box. To horizontal flat vertical installation of embedded parts, the application level calibration level, ensure the installation height of unity. After installation of lamps and lanterns to full seams, cannot leave gaps, completes the lights around the mask cleaning and protection. You both in the face of airports, hotels, business super, or lighting projects such as office buildings, schools, for the installation of the LED downlight this link, please send the above problems, thoughtful, in order to protect the smooth construction.
There are a wide variety of which are scientifically tested to have positive effects on the ability to ip65 led downlights. outside led downlights INFO CENTER is one of them.
You will find a wide variety of for sale for virtually any small led downlights needs. Keep in mind how you plan to use the , and talk with a professional about the model and features that are right for your application. Go to Rayven Led Downlights for on sale.
The unique connections between INFO CENTERmanufacturing and customers happen when you find ways to relate on a more personal and engaging level that goes beyond a product.
Foshan Rayven Lighting Co., Ltd prepares for every aspect of running a business, and this includes developing a sound understanding and ability to manage the financial aspects of our company, including financial analysis, taxes and budgeting.