The trend is beautiful and refreshing.

The various parameters of the standard hotel LED lighting lamps and lanterns of configuration

by:Rayven     2020-11-30
Hotel

LED lighting design, to the choice of LED lamps and lanterns and light design according to the hotel light environment features combined with lamps and lanterns of various parameters on the appropriate configuration. For the color temperature, intensity of illumination, lumens, color rendering index, light distribution and so on all needs to carry on the design according to the actual space function. So, in the process of construction of hotel lighting, lighting parameters of different space should take what kind of standard?

1, LED color temperature hotel lighting lamps and lanterns choose

for the hotel, the main purpose is to transit business and travel, is for the temporary home to rest. So the color temperature requirements and comfortable warmth. LED lighting hotel different space, should be given priority to with warm white light around 3000 k. In addition to wash bath can be more than 3500 k is white or cold white illuminant, other space should be warm white. Warm and comfortable.

2, LED the hotel lighting color rendering index

hotel lighting, LED lighting lamps and lanterns of color rendering index according to the requirements of the different functional Spaces is slightly different. In general need high color rendering index or bath rooms and restaurant, lobby lounge area can be slightly lower. Lobby, service desk, guest lounge area requirements, Ra> 85. Chinese and western restaurants Ra> color rendering index requirements; 90. The bathroom color rendering index requirements Ra> 90.

3, different function space hotel LED lighting illumination requirements

in the door and lobby and 1 m above the ground level, design illumination to reach 500 lux. Service desk illumination requirements: take 750 - commonly 1000Lux。 Generally take 300 - guest lounge area illumination requirements 500Lux。 Chinese restaurant of the general lighting illumination take 200 lux, general lighting illumination take 50 - western-style restaurant 100Lux。 Guest room illumination requirements generally take 50 - tone 100 lux, but local lighting, such as toilet glass lighting, in front of the head of a bed reading lighting should provide adequate illumination, these areas are desirable illuminance values of 300 lux.

4, about the LED hotel lighting light distribution standard

in light of different functional areas of the hotel, the intensity distribution of light distribution curve, light intensity in the center and half should have required parameters, such as light intensity. In general the lobby of the hotel the height is very high. For above the height 6 meters, beam Angle is too large will cause the ground light intensity is insufficient. For the guest room space such as if the beam Angle is too narrow, can cause the ground too bright, the problem of insufficient vertical illumination.

high if more than 6 m, suitable for a narrow beam of LED lighting lamps and lanterns, to provide a continuous, uniform brightness. Such as distance is 6 m, it light distribution curve at the center of the light intensity, 1 m above the ground should be not less than 500 CD; If no more than 6 m high jump, can consider to use ribbon or planar illuminator.


Rayven allocates customer service resources to the platform where their customers are most vocal.
Review Foshan Rayven Lighting Co., Ltd's progress at regular intervals, so we can continue with the strategies that work well and change or eliminate the ones that don't give the results we are looking for.
Foshan Rayven Lighting Co., Ltd will do this by managing our business with integrity and the highest ethical standards, while acting in a socially responsible manner with particular emphasis on the well-being of our teammates and the communities we serve.
We focus on operational procedure and manufacturing facilities of INFO CENTER.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: